CHAPTER 57    Testing SIP Signaling Calls
Authentication
Note: These parameters are applicable only if the 'Call Party' parameter (below) is configured to
Caller.
'Auto Register'
auto-register
[Test_Call_AutoRegister]
'Username'
user-name
[Test_Call_UserName]
'Password'
password
[Test_Call_Password]
Test Setting
'Call Party'
call-party
[Test_Call_CallParty]
Parameter
Description
[-1] Not Configured = The mode is according to the
'Alternative DTMF Method' and 'RFC 2833 Mode'
parameters of the IP Profile associated with the rule's
IP Group (see the 'IP Group' parameter above).
[0] RFC 2833 = (Default) The device sends the DTMF
digits using the RFC 2833 method (out-of-band).
[1] In Band = The device sends the DTMF digits in-
band (in the RTP stream).
Note:
The parameter is applicable only if you configure the
'Play' parameter to DTMF.
Playing DTMF digits requires DSP resources when
the DTMF method is In Band.
If the Test Call sends the SDP offer, the
recommended DTMF configuration of the associated
IP Profile is as follows:
For RFC 2833: 'RFC 2833 Mode' = Extend;
'Alternative DTMF Method' = As Is
For In Band: 'RFC 2833 Mode' = Disallow;
'Alternative DTMF Method' = As Is
If the Test Call receives the SDP offer, the
recommended configuration is as follows (i.e.,
incoming SDP offer determines the method): 'RFC
2833 Mode' = As Is; 'Alternative DTMF Method' = As
Is I
Enables automatic registration of the endpoint. The
endpoint can register to the device itself or to the
'Destination Address' or 'IP Group' parameter settings
(see above).
[0] Disable (default)
[1] Enable
Defines the authentication username.
The valid value is a string of up to 60 characters. By
default, no value is defined.
Defines the authentication password.
By default, no password is defined.
Defines whether the test endpoint is the initiator (caller) or
receiving side (called) of the test call.
[0] Caller (default)
- 844 -