CHAPTER 51    Reporting Information to External Party
Field
Local
Packet Loss
[608]
Local R
Factor
[625]
Local Round
Trip Delay
[609]
Local RTP
IP
[620]
Local RTP
Port
The maximum number of characters for Syslog tabular alignment is 10.
Displays the number of packets lost of the entire stream. The field is an integer
from 0 to 0xFFFFFFFF (-1 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "PackLoss" for Gateway Syslog and Local Storage,
and "LocalPackLoss" for SBC Syslog.
The maximum number of characters for Syslog tabular alignment is 10.
Displays the local R-factor conversation quality. The field is an integer from 0
to 120 (127 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "LocalRFactor".
If the RTCP XR feature is unavailable (not licensed or disabled), this R-
factor VoIP metric is not provided. Instead, the device sends the CDR field
with the value 127, meaning that information is unavailable.
The maximum number of characters for Syslog tabular alignment is 12.
Displays the average round-trip delay time of the entire RTP stream. The field
is an integer from 0 to 10000 ms (-1 if information is unavailable).
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "RTPdelay".
The maximum number of characters for Syslog tabular alignment is 9.
Displays the local RTP IP address.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END", "CALL_CONNECT",
"MEDIA_END", "MEDIA_START", and "MEDIA_END" CDR Report
Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "LocalRtpIp".
The maximum number of characters for Syslog tabular alignment is 20.
Displays the local RTP port. This field is an integer from 0 to 0xFFFF.
Note: