CHAPTER 60    Configuration Parameters Reference
[WelcomeMessage]
configure system > welcome-
msg
[UseProductName]
Parameter
Description
SNMP (restores default users and retains
other configured users):
1) Set acSysGenericINILine to
WEBPasswordControlViaSNMP = 1, and
reset the device with a flash burn (set
acSysActionSetResetControl to 1 and
acSysActionSetReset to 1).
2) Change the username and password in
the acSysWEBAccessEntry table. Use the
following format:
Username acSysWEBAccessUserName:
old/pass/new
Password acSysWEBAccessUserCode:
username/old/new
Defines a welcome message displayed on the Web
interface's Web Login page.
The format of the ini file table parameter is:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
[\WelcomeMessage]
For Example:
FORMAT WelcomeMessage_Index =
WelcomeMessage_Text
WelcomeMessage 1 =
"**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome
message ***" ;
WelcomeMessage 3 =
"**********************************" ;
For more information, see
Welcome
Message.
Note:
Each index row represents a line of text. Up to
20 lines (or rows) of text can be defined.
The configured text message must be enclosed
in double quotation marks (i.e., "...").
If the parameter is not configured, no Welcome
message is displayed.
Enables the option to customize the name of the
device (product) that appears in the management
interfaces.
[0] = Disabled (default).
[1] = Enables the display of a user-defined
name, which is configured by the
UserProductName parameter.
For more information, see
Name.