AudioCodes Mediant 4000 SBC User Manual page 809

Session border controllers
Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

CHAPTER 51    Reporting Information to External Party
Field
[400]
Global
Session ID
[309]
H323 ID
[306]
IP Group ID
[416]
IP Group
Name
[417]
"NONE"
"SBC" (SBC calls)
"TEST" (for Test Call calls)
"3WCONF" (three-way conferencing calls)
"SIPREC" (SIPRec calls)
"MOH" (Music-on-Hold calls)
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "EPTyp".
The maximum number of characters for Syslog tabular alignment is 10.
Displays the global session ID.
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format and Gateway CDR Format tables.
The field is applicable to SBC signaling and media, and Gateway CDRs.
The default field title is "h323-gw-id=" for RADIUS (A_ACCT_SESSION_
TIME).
The maximum number of characters for Syslog tabular alignment is 16.
For more information on the global session ID, see
Session ID over Multiple Devices
Displays the SIP ID to the RADIUS server. The field is a string.
Note:
The field is included in the default CDR.
The field is applicable only to ? CDR Report Types (Start Acc andStop
Acc).
The field is applicable only to RADIUS SBC and Gateway CDRs.
The default field title is "h323-gw-id for RADIUS.
The maximum number of characters for Syslog tabular alignment is 33.
Displays the IP Group ID. The field is an integer.
Note:
The field is optional and can be included in the CDR using the SBC CDR
Format and Gateway CDR Format tables.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The maximum number of characters for Syslog tabular alignment is 5.
Displays the IP Group name. The field is a string of up to 40 characters.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
- 776 -
Mediant 4000 SBC | User's Manual
Description
Enabling Same Call
on page 838.