CHAPTER 51 Reporting Information to External Party
Field
Signaling IP
DiffServ
[422]
SIP
Interface ID
[420]
SIP
Interface
Name
[433]
SIP Local
Tag
[445]
SIP Method
[806]
■
The maximum number of characters for Syslog tabular alignment is 35.
Displays the signaling IP DiffServ. The field value is an integer of up to 15
digits.
Note:
■
The field is included in the default CDR.
■
The field is applicable to all CDR Report Types.
■
The field is applicable only to SBC signaling and Gateway CDRs.
■
The default field title is "TxSigIPDiffServ".
■
The maximum number of characters for Syslog tabular alignment is 15.
Displays the SIP Interface table row index (integer).
Note:
■
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
■
The field is applicable to all CDR Report Types.
■
The field is applicable only to SBC signaling and Gateway CDRs.
■
The maximum number of characters for Syslog tabular alignment is 5.
Displays the SIP Interface name. The field value is a string of up to 40
characters.
Note:
■
The field is included in the default CDR.
■
The field is applicable to all CDR Report Types.
■
The field is applicable only to SBC signaling and Gateway CDRs.
■
The default field title is "SIPInterfaceId (name)".
■
The maximum number of characters for Syslog tabular alignment is 32.
Displays the 'tag' parameter of the SIP From / To headers that is generated by
the device in the outgoing SIP message . The field value is a string of up to 100
characters.
Note:
■
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
■
The field is applicable to all CDR Report Types, but it may not be added to
some Report Types in all call scenarios.
■
The field is applicable only to SBC signaling and Gateway CDRs.
■
The maximum number of characters for Syslog tabular alignment is 20.
Displays the SIP message type (method). The field value is a string of up to 10
characters:
■
"INVITE"
■
"OPTIONS"
■
"REGISTER"
■
"NOTIFY"
■
"INFO"
■
"SUBSCRIBE"
- 789 -
Mediant 4000 SBC | User's Manual
Description