CHAPTER 51    Reporting Information to External Party
Field
RTP IP
DiffServ
[624]
Session ID
[302]
Setup Time
[411]
"DIALOG_CONNECT ": The CDR is sent upon establishment of a non-
INVITE session (only when enabled, using the EnableNonCallCdr
parameter).
"MEDIA_START": The CDR is sent upon 200 OK response or early media
"MEDIA_UPDATE": The CDR is sent upon a re-INVITE message
"MEDIA_END": The CDR sent is upon a BYE message
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable to SBC media and signaling, and Gateway CDRs.
The default field title is "GWReportType" for Gateway Syslog and Local
Storage, "SBCReportType" for SBC Syslog and Local Storage, and
"MediaReportType" for SBC Syslog Media.
The maximum number of characters for Syslog tabular alignment is 15.
The field displays the RTP IP DiffServ. The valid value is an integer from 0 to
63.
Note:
The field is included in the default CDR.
The field is applicable to "CALL_END", "CALL_CONNECT", "MEDIA_
START", "MEDIA_UPDATE", "MEDIA_END" CDR Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "TxRTPIPDiffServ".
The maximum number of characters for Syslog tabular alignment is 15.
Displays the unique session ID. The field value is a string of up to 24
characters.
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable to SBC media and signaling, and Gateway CDRs.
The default field title is "SessionId".
The maximum number of characters for Syslog tabular alignment is 24.
Displays the date and time that the call was setup. The field value is a string of
up to 35 characters and presented in the following format:
<hh:mm:ss:ms> UTC <DDD> <MMM> <DD> <YYYY>. For example,
"17:00:49.052 UTC Thu Dec 14 2017"
Note:
To configure the time zone string (e.g., "UTC" - default, "GMT+1", and
"EST"), use the TimeZoneFormat parameter.
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "SetupTime"" for Syslog and Local Storage, and
"h323-setup-time=" for RADIUS.