Transfer High Assy (Pl8.1.20) Removal - Epson AcuLaser C8500 Service Manual

Color laser page printer
Hide thumbs Also See for AcuLaser C8500:
Table of Contents

Advertisement

EPSON AcuLaser C8500

3.2.11.2 TRANSFER HIGH ASSY (PL8.1.20) Removal

1. Remove the DRUM CARTRIDGE. (See Section 3.2.9.1.)
2. Remove the TENSION LEVER. (See Section 3.2.11.1.)
3. Remove the IBT INNER COVER ASSY. (See Section 3.2.5.6.)
4. Remove the FUSER ASSY. (See Section 3.2.12.1.)
5. Remove the BELT CLEANER ASSY. (See Section 3.2.11.3.)
6. Remove the 2ND BTR ASSY. (See Section 3.2.11.4.)
7. Pull out the MSI/REGI HIGH ASSY.
8. Disconnect the ADC SENSOR ASSY connector (P/J81) and connector (P/
J54) from the TR0 SENSOR. Then, remove the harness from clamps.
9. Remove the 4 screws (silver, w/collar, 8mm) securing the PANEL HIGH
ASSY, and remove the PANEL HIGH ASSY.
NOTE: Make sure the IBT BELT ASSY does not touch any other part while
performing the following. Never tough the surface of the IBT BELT
with your hands. (You may hold the assembly by the ribs on either
side.)
10. Lift the TRANSFER HIGH ASSY slightly and remove it by pulling forward.
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
Figure 3-68. TRANSFER HIGH ASSY Removal
Revision C
3-62