3.2.12.12 TEMP. SENSOR ASSY (PL9.2.6) Removal

1. Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2. Pull out the FUSER ASSY. (See Section 3.2.12.1.)
3. Remove the MAIN FUSER ASSY. (See Section 3.2.12.2.)
4. Remove the UPPER GUIDE ASSY. (See Section 3.2.12.3.)
5. Remove the FUSER UPPER ASSY. (See Section 3.2.12.4.)
6. Remove the H/R HEATER. (See Section 3.2.12.5.)
7. Remove the P/R HEATER. (See Section 3.2.12.6.)
8. Remove the LOWER GUIDE ASSY. (See Section 3.2.12.7.)
9. Remove the 2 screws (black, w/collar, 8mm) securing the FUSER
BOTTOM PLATE, remove the FUSER BOTTOM PLATE.
10. Disconnect the connector (P/J721,P/J722) from the FUSER EXIT
SENSOR-1/-2, unhook the harness from the FUSER BOTTOM PLATE,
and remove the TEMP. SENSOR ASSY.
After mounting, adjustment as described in Section 3.3.1
A D J U S T M E N T
R E Q U I R E D
"NIP Pressure of the MAIN FUSER ASSY".
C H E C K
When mounting, hook the harness on the FUSER BOTTOM
P O I N T
PLATE hook so there is no slack in the harness.
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
Figure 3-89. TEMP. SENSOR ASSY Removal