3.2.14.7 ROTARY MOTOR ASSY (PL11.1.20) Removal

1. Remove the REAR COVER ASSY. (See Section 3.2.5.8.)
2. Disconnect the connector (P/J247) of the ROTARY MOTOR ASSY.
3. Remove the 3 screws (gold, 6mm) securing the ROTARY MOTOR ASSY,
and remove the ROTARY MOTOR ASSY.
C H E C K
Be careful not to pinch the harness when mounting.
P O I N T
Figure 3-113. ROTARY MOTOR ASSY Removal
Disassembly/Assembly/Adjustment

3.2.14.8 ROTARY MOTOR DRIVE PWB (PL11.1.21) Removal

1. Remove the REAR COVER ASSY. (See Section 3.2.5.8.)
NOTE: The ROTARY MOTOR PWB and printer remain connected by a
harness. Be careful not to pull too far apart while performing the
following.
2. Remove the screw (silver, w/collar, 8mm) securing the ROTARY MOTOR
DRIVE PWB, and separate the ROTARY MOTOR DRIVE PWB from the
printer.
3. Disconnect the 3 connectors (P/J245, P/J246, P/J247) of the ROTARY
MOTOR DRIVE PWB, and remove the ROTARY MOTOR DRIVE PWB.
Figure 3-114. ROTARY MOTOR DRIVE PWB Removal