Epson AcuLaser C8500 Service Manual page 304

Color laser page printer
Hide thumbs Also See for AcuLaser C8500:
Table of Contents

Advertisement

EPSON AcuLaser C8500
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
When status data is
Name
(Hex)
REAR_FAN
60
DEVE. FAN
_SPEED
Set DEVE. FAN SLOW-
SPEED signal to Low.
REAR_FAN
61
DEVE. FAN
Set DEVE. FAN ON
signal to Low.
PH_MOT
62
FUSER MOTOR ASSY,
P/H MOTOR ASSY
_SPEED1
Set FUSER-P/H
MOTOR SPEED signal
to Low.
FUSER_FAN_1
63
FUSER FAN-1
Set FUSER FAN-1 ON
signal to Low.
Chapter 4
Diagnostics
Function Item
[High]
Check Method
<WARNING>
Check visually that the
rotation of the DEVE.
FAN goes to high
speed.
(During executing with
code [61], executing
this code changes the
DEVE. FAN to high
speed.)
<WARNING>
Check visually the
rotation of the DEVE.
FAN.
<WARNING>
<CAUTION>
Check by the change
in operational sound or
visually that the
rotation of two motors
goes to low speed (1/3
speed).
(During executing with
code [53] and [57],
executing this code
changes the FUSER
MOTOR ASSY and
the P/H MOTOR
ASSY to 1/3 speed.)
<WARNING>
Check visually the
rotation (low speed) of
the FUSER FAN-1.
Table 4-10. Digital Output Test Device Code
Digital Output Test [DIAGSTART : [90 02 XX] , DIAGSTOP : [91 02 XX] ]
Code
When status data is
Name
(Hex)
FUSER_FAN_2
64
FUSER CHUTE FAN
Set FUSER CHUTE
FAN ON signal to Low.
FUSER_FAN
65
FUSER FAN-1
_SPEED
Set FUSER FAN-1
SLOW-SPEED signal to
Low.
IBT_CLEANER_S
66
CLEANER CAM
OL
SOLENOID
Set CLEANER CAM
SOLENOID ON signal
to Low.
ADC_CLEAN
67
ADC SENSOR ASSY
_SOL
Set ADC SOLENOID
ON signal to Low.
BTR_2ND_CL
70
BTR CAM CLUTCH
Set BTR CAM CLUTCH
ON signal to Low.
ERASE_LAMP
71
ERASE LAMP ASSY
Set ERASE LAMP ON
signal to Low.
ADC_LED
72
ADC SENSOR ASSY
Set ADC LED ON signal
to Low.
Revision C
Function Item
[High]
Check Method
<WARNING>
Check visually the
rotation of the FUSER
CHUTE FAN.
<WARNING>
Check visually that the
rotation of the FUSER
FAN-1 goes to high
speed.
(During executing with
code [63], executing
this code changes the
FUSER FAN-1 to high
speed.)
<CAUTION>
Check by operational
sound that the
solenoid is operating.
Check by operational
sound that the
solenoid is operating.
(Repeat ON/OFF with
0.12sec/1sec.)
<CAUTION>
Check by operational
sound that the clutch is
operating.
Check LED light up.
(Do it while executing
a code [54].)
Check the signal.
(LED of the ADC
Sensor is turned on.)
4-36

Advertisement

Table of Contents
loading

Table of Contents