EPSON AcuLaser C8500
3.2.7.3 FEED ROLL (PL3.1.31) Removal
1. Remove the UNIVERSAL CASSETTE. (See Section 3.2.6.1.)
2. Remove the FRONT MID COVER. (See Section 3.2.5.2.)
3. Remove 1 screw (silver, cup head, 6 mm) securing the TRAY SENSOR
BRACKET and remove the TRAY SENSOR BRACKET.
NOTE: In the following step, be careful with the metal plate as you maybe
hurt with its sharp edge.
4. Insert your hand in the UNIVERSAL CASSETTE slot , release the hook on
the FEED ROLL, and remove the FEED ROLL.
C H E C K
When installing the FEED ROLL, make sure the arrow
P O I N T
marked on the side of the roll is facing to the rotating
direction.
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
Figure 3-24. FEED ROLL Removal
Revision C
3-27