EPSON AcuLaser C8500

3.2.12.13 EXCHANGE CHUTE (PL9.3.17) Removal

1. Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2. Pull out the FUSER ASSY. (See Section 3.2.12.1.)
3. Remove the MAIN FUSER ASSY. (See Section 3.2.12.2.)
4. Remove the 2 screws (gold, tapping, 10mm) securing the FUSER FRONT
RAIL, and remove the FUSER FRONT RAIL.
5. Remove the screw (gold, tapping, 10mm) securing EXCHANGE
STOPPER-F, and remove EXCHANGE STOPPER-F.
6. Remove the screw (gold, tapping, 10mm) securing EXCHANGE
STOPPER-R, and remove EXCHANGE STOPPER-R.
Disassembly/Assembly/Adjustment
NOTE: Be careful not to damage the front/rear hinges of the exchange cute
7. Remove the EXCHANGE CHUTE by pulling straight out from the right
TBK4AFFA
Figure 3-90. EXCHANGE CHUTE Removal
Disassembly/Assembly Procedures
while performing the following.
side.
C H E C K
Insert the U-shaped parts on the front and rear of the
P O I N T
EXCHANGE CHUTE securely into the plunger when
mounting the EXCHANGE CHUTE.