EPSON AcuLaser C8500

4.2.5.8 Analog Input Test

This lets you detect the signal level of sensors and output monitors that
have analog signals.
NOTE: Do use this without this manual or the wise instructed.
Table 4-11. Analog Input Test
DIAGON command: [75]
DIAGSTART command (Analog Input Test) : [90 03 XX]
DIAGSTOP command (Analog Input Test) : Unnecessary
Parameter
Function
1
Diagnostics Type
2
Code_AI
3
Data
Status present ( [90 03 XX XX XX])
NOTE: Status data is displayed in 2 bytes in order from the least
significant.
Chapter 4
Diagnostics
DIAGOFF command: [76]
Data (hex)
02 : Digital Output Test
Device code (See the next section [2.6.9].)
[Status only] data
EX) [Command]
91 03 01
ADC_SRN
Analog Input Test
DIAGSTART Command
EX) [Status]
90 03 01 1F 01
DATA (011F)
ADC_SRN
Analog Input Test
DIAGSTART Command
Revision C