1.6.3.7 Maintenance Menu

This menu is indicated and selected only while the Maintenance Mode is
activated by the service function at power-on. To eliminate this menu from the
setting menu option, turn the printer off and then back on, and the printer
returns to the normal mode. This menu is intended for servicers only.
Using this menu, you can reset several counters. When
C A U T I O N
clearing any counter value, be sure to open the Front cover,
check that the cover open error is indicated, and then close
the cover. Otherwise, the reset operation is not effective.
(This is due to engine specifications.)
ENGINE STATUS SHEET
Pressing the Enter button lets the printer print Engine Status Sheet. lf language
data is still in the printer, the sheet will eject. Make sure the printer is free from
any engine related service-call error in the normal mode (any mode other than
the maintenance mode) before entering and executing the "Maintenance
Menu". Engine Status Sheet will be printed with RIT, toner-save, and resolution
remained in the current settings; and all other set to their factory defaults. The
user-default environment remains in effect after printing is completed. The
indication on the LED blinks while printing is in progress. The printed sheet will
show the count values of the counter on each unit in the engine. The Engine
Status Sheet is always printed in English regardless of the Setup menu's Lang
setting.
2ND BTR CLEAR
Resets the 2nd BTR counter. The maintenance engineer must reset this
counter after replacing the 2nd BTR with a new one. When the reset operation
is done, the printer reboots. Then, be sure to open the Front Cover and close it
to make the operation effective.
PRODUCT DESCRIPTIONS
IBT CLEANER CLEAR
Resets the IBT Cleaner counter. The maintenance engineer must reset this
counter after replacing the IBT Cleaner with a new one. When the reset
operation is done, the printer reboots. Then, be sure to open the Front Cover
and close it to make the operation effective.
IBT BELT CLEANER
Resets the IBT Belt Cleaner counter. The maintenance engineer must reset
this counter after replacing the IBT Belt Cleaner with a new one. When the
reset operation is done, the printer reboots. Then, be sure to open the Front
Cover and close it to make the operation effective.
C DEVELOPMENT CLEAR
Resets the C Development counter. The maintenance engineer must reset this
counter after replacing the C Development with a new one. When the reset
operation is done, the printer reboots. Then, be sure to open the Front Cover
and close it to make the operation effective.
M DEVELOPMENT CLEAR
Resets the M Development counter. The maintenance engineer must reset this
counter after replacing the M Development with a new one. When the reset
operation is done, the printer reboots. Then, be sure to open the Front Cover
and close it to make the operation effective.
Y DEVELOPMENT CLEAR
Resets the Y Development counter. The maintenance engineer must reset this
counter after replacing the Y Development with a new one. When the reset
operation is done, the printer reboots. Then, be sure to open the Front Cover
and close it to make the operation effective.