3.2.12.16 CLEANER CAM ASSY (PL9.4.25) Removal

1. Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2. Remove the FUSER ASSY. (See Section 3.2.12.1.)
3. Remove the MAIN FUSER ASSY. (See Section 3.2.12.2.)
4. Remove the CLEANER CAM SOLENOID. (See Section 3.2.12.15.)
5. Remove the 2 screws (gold, tapping, 10mm) securing the FUSER FRONT
RAIL, and remove the FUSER FRONT RAIL.
NOTE: Be sure not to drop and lose the CLEANER CAM PIN when removing
the CLEANER CAM in the following step of the procedure.
6. Remove the E-ring securing the CLEANER CAM. Remove the CLEANER
CAM, CLEANER CAM PIN, and CLN CAM BEARING-F.
7. Remove the CLEANER CAM ASSY together with CLN CAM BEARING-F
by pulling straight out from the rear.
8. Remove CLN CAM BEARING-F from the CLEANER CAM ASSY.
C H E C K
The right/left direction of the cam must be adjusted after
P O I N T
mounting it.
Disassembly/Assembly/Adjustment
Disassembly/Assembly Procedures
Figure 3-93. CLEANER CAM ASSY Removal