Analog Output Test Device Code - Epson AcuLaser C8500 Service Manual

Color laser page printer
Hide thumbs Also See for AcuLaser C8500:
Table of Contents

Advertisement

EPSON AcuLaser C8500
During high voltage output, never touch parts with high
W A R N I N G
voltage output or energized with high voltage.
When the laser is operating, always keep all covers in
place.
Never touch an operating drive section .
NOTE: To prevent electrification exhaustion, never execute [BCR] ON,
[ERASE LAMP ASSY] ON, and [ROS ASSY LD] ON when
[PROCESS DRIVE ASSY] is OFF.
NOTE: With [PROCESS DRIVE ASSY] ON, [FUSER-P/H MOTOR] ON,
[DEVE. CLUTHC ASSY] ON, and at each color development
position, never turn only [DB output (AC component)] ON or turn
both [DB output (AC component)] and [DB output (DC
component)] ON.
NOTE: Never turn ON for 10 seconds or more the [DISPENSE MOTOR
ASSY] at each color's development position. Otherwise a toner
jam or gear damage may occur.
NOTE: Never turn ON the 1ST BTR with the [PROCESS DRIVE ASSY]
OFF. Otherwise the IBT BELT ASSY may be damaged.
NOTE: Never turn ON the 2ND BTR with the [PROCESS DRIVE ASSY]
OFF and the [FUSER-P/H MOTOR] OFF. Otherwise the IBT
BELT ASSY may be damaged.
NOTE: To prevent dirt from getting into the printer and damage to the
gears caused by improper meshing, never execute [FUSER-P/H
MOTOR] ON or [DEVE. CLUTCH ASSY] ON when slightly
shifted from development position for each color.
Chapter 4
Diagnostics

4.2.5.11 Analog Output Test Device Code

W A R N I N G
For check methods with <WARNING> <CAUTION>
indicated, check thoroughly the WARNINGs and
CAUTIONs in the Section 4.2.5.6 "Digital Output Test"
so as to execute without causing any problems.
Analog Output Test Device Code
Table 4-14.
Analog Output Test [DIAGSTAR : [90 04 XX] , DIAGSTOP : 91 04 XX XX]
Code
Functional Item
Name
(Hex)
Check Signal
Data Range
BTR_1ST_OUT
00
HVPS
Output the 1BTR CONT
signal with a value based
on data.
00-FFh (0-4.1[VDC]
BTR_2ND_OUT
01
HVPS
Output the 2BTR CONT
signal with a value based
on data.
00-FFh (0-4.1[VDC])
BCR_DC_OUT
02
HVPS
Output the BCR DC
CONT signal with a
value based on data.
00-FFh (0-4.1[VDC])
Revision C
Check Method
<WARNING> <CAUTION>
Check with the 1BTR
CONT signal.
(Do 1ST BTR output when
you execute this DIAG at
the same time with Digital
Output Test [54] and [0B].)
<WARNING> <CAUTION>
Check with the 2BTR
CONT signal.
(Do 2ND BTR output when
you execute this DIAG at
the same time with Digital
Output Test [54] and [0A].)
<WARNING> <CAUTION>
Check with the BCR DC
CONT signal.
(Do BCR output when you
execute this DIAG at the
same time with Digital
Output Test [54] and [0E].)
4-44