EPSON AcuLaser C8500
3.2.12.9 FUSER EXIT SENSOR-2 (PL9.2.4) Removal
1. Remove the EXIT TRAY ASSY. (See Section 3.2.13.1.)
2. Pull out the FUSER ASSY.
3. Remove the MAIN FUSER ASSY. (See Section 3.2.12.2.)
4. Remove the UPPER GUIDE ASSY. (See Section 3.2.12.3.)
5. Remove the LOWER GUIDE ASSY. (See Section 3.2.12.7.)
6. Disconnect the FUSER EXIT SENSOR-2 connector (P/J 722).
7. Unhook FUSER EXIT SENSOR-2 from the FUSER BOTTOM PLATE and
remove.
Figure 3-86. FUSER EXIT SENSOR-2 Removal
Disassembly/Assembly/Adjustment
TBK41ABFA
Disassembly/Assembly Procedures
Revision C
3-77