Analog Input Test Device Code - Epson AcuLaser C8500 Service Manual

Color laser page printer
Hide thumbs Also See for AcuLaser C8500:
Table of Contents

Advertisement

EPSON AcuLaser C8500

4.2.5.9 Analog Input Test Device Code

W A R N I N G
For items with <WARNING> <CAUTION> indicated,
check thoroughly the WARNINGs and CAUTIONs for
the output test so as to execute without causing any
problems.
Table 4-12. Analog Input Test Device Code
Analog Input Test [DIAGSTAR : [90 03 XX] , DIAGSTOP : Unnecessary]
Code
Functional Item
Name
(Hex)
Check Signal
Data Range
BTR_2ND_IN
00
HVPS (Secondary
transfer electric current
monitor)
2BTR I MONI Signal
0000-03FFh (0-4.1[V])
ADC_SNR
01
ADC Sensor (ADC
SENSOR ASSY)
ADC SIG Signal
0000-03FFh(0-4.1[VDC])
PAP_SIZE_SW_1
02
SIZE SWITCH ASSY
(Cassette 1Cassette 2)
[1] SIZE SWITCH Signal
0000-00FFh(0-4.1[V])
See "7.2 Paper Size
Control" in Chapter 10.
Chapter 4
Diagnostics
Check Method
<WARNING> <CAUTION>
Conduct 2ND BTR output
with Digital Output Test
[54] and [A0] and Analog
Output Test [01], and
check the data with this
diagnostic.
Check by this DIAG while
executing Digital Output
Test with the code [72].
Switch ON/OFF the four
Cassette 1 SIZE SWITCH
ASSY paper size switches
and check the data with
this diagnostic.
Table 4-12. Analog Input Test Device Code
Analog Input Test [DIAGSTAR : [90 03 XX] , DIAGSTOP : Unnecessary]
Code
Functional Item
Name
(Hex)
Check Signal
Data Range
HR_THERMISTE
03
TEMP. SENSOR ASSY
R
TEMP. Signal
0000-00FFh (0-
4.1[VDC])
ENV_THERM
04
ENVIRONMENT
SENSOR (Temperature)
ENVIRONMENT TEMP.
0000-00FFh (0-
4.1[VDC])
_5V_BUNATSU
05
5VDC power supply
monitor
5VDC pressure inside
MCU PWB
0000-00FFh (0-
4.1[VDC])
ENV_HUMIDITY
06
ENVIRONMENT
SENSOR
(Humidity)
HUMIDITY SENSOR
signal.
0000-00FFh (0-
4.1[VDC])
BTR_1ST_IN
07
HVPS (First transfer
electric current monitor)
1BTR I MONI Signal
0000-03FFh (0-4.1[V])
Revision C
Check Method
Check data.
[Note : When
DigitalOutputTest [46] is
executed, it becomes the
sermister breakage
detection mode, and
becomes the [00EAh]
above in the case of the
breakage.]
Check data.
-
Measure the error of the
5VDC power supply, and
correct data on the code
[02].
It usually becomes 00C9-
00DE (3.23V-3.57V).
Check data.
<WARNING> <CAUTION>
Conduct 1ST BTR output
with Digital Output Test
[54] and Analog Output
Test [00], and check the
data with this diagnostic.
4-41

Advertisement

Table of Contents
loading

Table of Contents