Epson AcuLaser C8500 Service Manual page 322

Color laser page printer
Hide thumbs Also See for AcuLaser C8500:
Table of Contents

Advertisement

EPSON AcuLaser C8500
Table 4-18. NVM List
EEPROM Read([90 05 XX XX]), EEPROM Write([90 06 XX XX YY XX (XX XXXX)])
Can/
Cannot
NVM No.
Data
Use
(Hex)
Byte
Description of Data
X
10
1
REGI. SENSOR Jam ([C4-
00-10])time
(000A)
adjustment(Duplex)
Detection timing becomes
early by data small.
X
11
1
2UP Paper Pitch time
adjustment (Cassette 1)
(000B)
The space of the form of 2UP
becomes small by data small.
X
12
1
REGI. SENSOR Jam ([C4-
20-00])time
(000C)
adjustment(Feeder)
Detection timing becomes
early by data small.
X
13
1
PITCH SENSOR Check time
adjustment(MSI)
(000D)
Check time becomes early by
data small.
X
14
1
PICK UP CLUTCH On time
adjustment(MSI)
(000E)
ON timing after the stop
becomes early by data small.
X
15
1
FUSER EXIT SENSOR wind
Jam
(000F)
([C4-40-00])time adjustment
Detection timing becomes
early by data small.
X
16
1
OHP detection excuse switch
(0010)
0:ON(standard)
1:OFF
2:ON(unique)
Chapter 4
Diagnostics
Set
Function
Range
(Hex)
Default
Units
(Hex)
-
(00)
8.8msec
-
51
(33)
0.988ms
ec
-
(00)
8.8msec
-
(00)
8.8msec
-
(00)
8.8msec
-
(00)
8.8msec
0, 1,
(00)
-
EEPROM Read([90 05 XX XX]), EEPROM Write([90 06 XX XX YY XX (XX XXXX)])
Can/
Cannot
NVM No.
Use
(Hex)
0
X
18
(0011)
X
19
(0013)
20
(0014)
0
21
(0015)
0
22
(0016)
0
23
(0017)
0
24
(0018)
0
Table 4-18. NVM List
Function
Data
Byte
Description of Data
1
A code by the country
0:Japan
1:Others
1
Image area choice
0:Standerd
1:Wide
1
Side Registration adjustment
(cassette 1)
An image is moved by data
small in the left end direction.
1
Side Registration adjustment
(cassette 2)
An image is moved by data
small in the left end direction.
1
Side Registration adjustment
(cassette 3 )
An image is moved by data
small in the left end direction.
1
Side Registration
adjustment(MSI)
An image is moved by data
small in the left end direction.
1
ªSide Registration
adjustment(Duplex)
An image is moved by data
small in the left end direction.
Revision C
Set
Range
(Hex)
Default
Units
(Hex)
0, 1
0
(00)
-
0, 1
1
(01)
-
0-64
33
(00-40)
(21)
0.17mm
0-64
35
(00-40)
(23)
0.17mm
0-64
36
(00-40)
(24)
0.17mm
0-64
32
(00-40)
(20)
0.17mm
0-64
17
(00-40)
(11)
0.17mm
4-54

Advertisement

Table of Contents
loading

Table of Contents