EPSON AcuLaser C8500
Table 4-18. NVM List
EEPROM Read([90 05 XX XX]), EEPROM Write([90 06 XX XX YY XX (XX XXXX)])
Can/
Cannot
NVM No.
Data
Use
(Hex)
Byte
Description of Data
X
360
1
1STEP offset value with 2ND
BTR offset level
(0168)
[3-10].(Coat paper)
Offset value (voltage)
becomes small by data small.
X
381
1
1STEP offset value with 2ND
BTR offset level
(017D)
[3-10].(Cardboard)
Offset value (voltage)
becomes small by data small.
X
382
1
1STEP offset value with 2ND
BTR offset level
(017E)
[3-10].(Envelope)
Offset value (voltage)
becomes small by data small.
X
383
1
1STEP offset value with 2ND
BTR offset level
(017F)
[3-10].(Label)
Offset value (voltage)
becomes small by data small.
X
384
1
1STEP offset value with 2ND
BTR offset level
(0180)
[3-10].(Postcard)
Offset value (voltage)
becomes small by data small.
X
385
1
1STEP offset value with 2ND
BTR offset level
(0181)
[3-10].(OHP)
Offset value (voltage)
becomes small by data small.
Chapter 4
Diagnostics
Set
Function
Range
(Hex)
Default
Units
(Hex)
0-30
15
(00-1E)
(0F)
13VDC
0-30
15
(00-1E)
(0F)
13VDC
0-30
15
(00-1E)
(0F)
13VDC
0-30
15
(00-1E)
(0F)
13VDC
0-30
15
(00-1E)
(0F)
13VDC
0-30
15
(00-1E)
(0F)
13VDC
Table 4-18. NVM List
EEPROM Read([90 05 XX XX]), EEPROM Write([90 06 XX XX YY XX (XX XXXX)])
Can/
Cannot
NVM No.
Data
Use
(Hex)
Byte
Description of Data
X
386
1
1STEP offset value with 2ND
BTR offset level
(0182)
[1-3].(Normal paper)
Offset value (voltage)
becomes small by data small.
X
387
1
1STEP offset value with 2ND
BTR offset level
(0183)
[1-3].(Coat paper)
Offset value (voltage)
becomes small by data small.
X
388
1
1STEP offset value with 2ND
BTR offset level
(0184)
[1-3].(Cardboard)
Offset value (voltage)
becomes small by data small.
X
389
1
1STEP offset value with 2ND
BTR offset level
(0185)
[1-3].(Envelope)
Offset value (voltage)
becomes small by data small.
X
390
1
1STEP offset value with 2ND
BTR offset level
(0186)
[1-3].(Label)
Offset value (voltage)
becomes small by data small.
X
391
1
1STEP offset value with 2ND
BTR offset level
(0187)
[1-3].(Postcard)
Offset value (voltage)
becomes small by data small.
Revision C
Set
Function
Range
(Hex)
Default
Units
(Hex)
0-23
31
(00-17)
(1F)
13VDC
0-23
31
(00-17)
(1F)
13VDC
0-23
31
(00-17)
(1F)
13VDC
0-23
31
(00-17)
(1F)
13VDC
0-23
31
(00-17)
(1F)
13VDC
0-23
31
(00-17)
(1F)
13VDC
4-60

Advertisement

Table of Contents
loading

Table of Contents