Chapter 2

2.1.3 Selecting the Site of Installation

imagePRESS C1 P / imagePRESS C1 / imagePRESS C1+ (Printer) / imagePRESS C1+
1. If possible, check the planned site of installation before delivering the machine.
(1) The power supply main plug (back side of the main body), is rated as indicated and the power outlet can be connected exclusively to the machine, is 100V/
15A or more for 100V machine, 120V to 127V/15.1A or more for 120V machine, 220 to 240V/9.2 or more for 230V machine.
(2) The sub power supply (left side of the main body), rated as indicated and must be a power outlet that may used exclusively for the machine: 100 V/2.9 A or
more for more the 100 V machine; 120 to 127 V/2.6 A or more for the 120V machine; 220 to 240 V/1.3 A or more for the 230V machine.
230V
1.3A
120V
2.6A
100V
2.9A
SUB
(3) There must be a grounding terminal for the machine.
Targets of Grounding
(a) Grounding terminal of power outlet
(b) The grounding terminal finished to Category D
Do not connect the grounding cord to the gas pipe.
2. Installation environment must be with in the following range. Avoid the close location to the faucet, water heater, humidifier or refrigerator.
Assured range of operation/image: temperature 15.0 to 30.0 deg C, humidity 5 to 80%
3. The area near the source of fire, place where dust gathers, place where ammonia gas generates, place exposed to the direct sunlight should be avoided. If the place
is exposed to the direct sunlight, it is better to hang a curtain in the window.
4. Although the ozone level generating in using this equipment does not affect human bodies, long-hours operation in a poorly-ventilated room may cause some
odor to be sensed. Ventilation should be done to keep a comfortable work environment.
5. The foot of the host machine should not get off the floor. The host machine should be kept in a horizontal status.
6. Allocate enough space for service operation of the host machine.
The site must provide enough space for maintenance work. The dimensions in the diagram below are minimum dimensions, and it is ideal to provide space larger
than indicated.
(a) Main body
(b) Main body + Paper Deck + Puncher + Saddle Finisher
2-4
230V
9.2A
120V
15.1A
100V
15A
MAIN
F-2-3
500 mm or more
1,756 mm
F-2-4
100 mm or more
500 mm or more
0012-5931