3.6.3

Detection of Abnormality

When something abnormal has occurred in the equipment, the symbols corresponding to the type of
abnormality are displayed.
[ 1 ] Types of abnormality
1. Abnormality cleared without turning OFF the door switch
(A) Add paper
2. Abnormality not cleared without turning OFF the door switch
(B) Pick-up failure in bypass
(C) Misfeed in equipment
(D) Replace the toner cartridge
(E) Developer unit not installed properly
3. Abnormality not cleared without turning OFF the main switch
(F) Call for service
[ 2 ] Description of abnormality
(A) Add paper
[In cases of the equipment drawer] (When drawer is not installed)
Drawer empty sensor detects the presence or absence of paper.
No drawer detected
"Add paper" is displayed
The LED on the control panel corresponding to the drawer blinks
[START] button disabled
[In cases of the equipment drawer] (When the drawer is installed)
Drawer detected
Paper empty sensor OFF
"Add paper" is displayed
The LED on the control panel corresponding to the drawer blinks
[START] button disabled
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved