5.12.2
Restrictions for the PM counter-related self-diagnosis codes
As for the following PM counter-related self-diagnosis codes, when their sub code 0 (present number of
output pages) is initialized from the setting mode (08), the numbers of sub code 8 (number of times
replaced) are not counted up.
<PM counter-related self-diagnosis codes>
•
6250: Photosensitive drum (K)
•
6258: Drum blade cleaner (K)
•
6272: Drum separation claw
•
6274: Charger grid (K)
•
6282: Charger (wire/needle) (K)
•
6298: Ozone filter
•
6300: Developer (K)
•
6314: Transfer (Wire/Belt/Roller)
•
6346: Upper heat roller
•
6350: Press roller
•
6368: Upper heat roller separation claw
•
6382: P/U roller (ADF)
•
6384: Paper feed roller (ADF)
•
6386: Separation roller (ADF)
•
6398: Paper feed roller (1st CST)
•
6406: Separation roller (1st CST)
•
6408: Separation pad (2nd CST)
•
6416: Separation pad (SFB)
•
6424: Paper feed roller (SFB)
•
6436: Drum recovery blade
•
6470: Fuser roller bushing
[Procedure to be restricted]
The below procedure is described taking the PM counter for the developer material (08-6300) as an
example.
1. Confirm the value of the sub code 8 of 08-6300.
2. Replace the developer material.
3. Restart the equipment with the setting mode (08) and set "0" in the sub code 0 of 08-6300.
[Countermeasure]
Clear the PM counter in the PM support mode (6S).
Procedure
(1)
Start the equipment with the PM support mode (6S).
P. 7-2 "7.2 PM Support Mode (6S)"
(2)
Key in "2" and press the [START] button.
(3)
Select the part to be replaced and press the [Right] arrow button.
(4)
Select "RESET" listed in the lowest part of the menu and press the [Right] arrow button.
(5)
Press the [OK] button.
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved