Toshiba e-STUDIO2006 Service Manual page 581

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

05/08
Mode
Element
Sub element
08
Setting
Process
Development Toner near empty
mode
08
Setting
Process
Development Toner near empty
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Sub-
Item
Subitem
Code
code
5155
-
5156
3
Fusing correction
5210
0
control time
immediately after
warming-up
Fusing correction
5210
1
control time
immediately after
warming-up
Correction of
5337
0
temperature rising
prevention (Latest
value)
Correction of
5337
1
temperature rising
prevention (Latest
value)
5469
-
Default
Acceptable
Details
value
value
Toner near empty
1
0-3
threshold setting
Fine adjustment
100
50-150
ofthreshold
fordisplaying
remainingtoner and
toner nearempty
Temperature correction
2
0-10
Maximum time of lamp
2
0-10
ON
Ready
0
0-15
Printing
0
0-15
Low power
0
0-1
consumption control
14-1-61
SRAM
Contents
M
Sets the timing for when the toner near empty display
appears. The larger the value, the later the display appears.
0: Longer *1
1: Center
2: Shorter *2
3: No detection
*1: The period of time (number of counts) from the
appearance of the near empty display to actually running
out of toner is longer (larger) than that of "center".
*2: The period of time (number of counts) from the
appearance of the near empty display to actually running
out of toner is shorter (smaller) than that of "center".
M
Adjusts the threshold value for displaying remaining amount
of toner and toner near empty. Display threshold value =
default threshold value x setting value/100 (unit: %)
50: Setting value x 0.5
100: Setting value x 1.0
150: Setting value x 1.5
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
M
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
M
o
o
o
o
o
0: 0
C 1: -1
C 2: -2
C 3: -3
C 4: -4
C 5: -5
o
o
o
o
-7
C 8: -8
C 9: -9
C 10: -10
C 11: -11
o
o
o
13
C 14: -14
C 15: -15
C
M
o
o
o
o
o
0: 0
C 1: -1
C 2: -2
C 3: -3
C 4: -4
C 5: -5
o
o
o
o
-7
C 8: -8
C 9: -9
C 10: -10
C 11: -11
o
o
o
13
C 14: -14
C 15: -15
C
M
This code is used when using low power consumption
control. Note that inconsistent fusing may occur if the fuser
roller temperature is low. Use the above default value,
unless otherwise required.
0: Invalid, 1: Valid
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
20L/
20H/
Proce
23L/
23H/
dure
25L
25H
1
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
o
o
14
Y
Y
C 6: -6
C 7:
o
o
C 12: -12
C 13: -
o
o
14
Y
Y
C 6: -6
C 7:
o
o
C 12: -12
C 13: -
1
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507