4.10.2

ADU sensor (S8)

(1)
Remove the ADU.
 P. 4-116 "4.10.1 Automatic duplexing unit
(ADU)"
(2)
Unplug 1 connector and release 3 latches
and remove the ADU sensor [1].
4.10.3
Fuser guide unit
(1)
Remove 1 screw and remove the "fuser
guide unit" [1] that is attached to the fuser.