5.10.3

Functions

[A] Set Serial Number
When replacing MAIN board, select this to set the serial number of the equipment since it must be done
in advance of recovery from flash memory backup data.
Clear flash memory first and then set the serial number in this mode.
[B] Clear SRAM
Select this to clear all flash memory data when replacing the main board flash memory.
Replace the MAIN board and then clear the flash memory data.
After clearing the flash memory data, initialize flash memory following its replacement procedure.
Remarks:
SRAM CLEAR
SET SERIAL NUMBER
CLEAR SRAM
Though the menu includes an "SRAM" item, the machine
is actually equipped with Flash memory, not SRAM.
Notes:
When the memory has been cleared in the Assist Mode (6C), check the items below and change
the value of the following codes accordingly:
08-3134 (Scan motor gear) <20L/23L/25L/20H/23H/25H only>
0: One-gear
1: Two-gear
08-9063 (Installation of the fax function)
0: Not installed
1: Installed