8.3.11

Process related service call

[CE50] Temperature/humidity sensor abnormality
Classification
Process related service call
Check Item
Is the connector CN24 on the
MAIN board or the connector of the
temperature/humidity sensor
disconnected?
Is the harness between the MAIN
board and the temperature/
humidity sensor disconnected?
Replacement part
Temperature/humidity sensor
MAIN board
[CE90] Drum thermistor abnormal
Classification
Process related service call
Check Item
MAIN board
Replacement part
Drum thermistor
MAIN board
[C970] High-voltage transformer abnormality
Classification
Process related service call
Check Item
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Temperature/humidity sensor abnormality
Result
Yes
1. Connect the connector securely. Replace the
harness.
No
1. Replace the temperature/humidity sensor.
2. Replace the MAIN board.
Drum thermistor abnormal
1. Is the connector CN24 on the MAIN board, or the connector
of the drum thermistor disconnected?
High-voltage transformer abnormality
1. Is the main charger installed securely?
2. Check if the spring of high-voltage supply contact point is
deformed.
3. Check if the needle electrode is broken or the main charger
grid is deformed.
4. Check if any foreign matters is on the needle electrode or
the main charger grid.
5. Check if the transfer roller and the separation needle are
installed securely.
6. Check if the transfer roller or the separation needle is
removed.
7. Check if there is any foreign matter attached on the transfer
roller or the separation needle.
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
8 - 49
Contents
Measure
Remark
Contents
Measure
Remark
Contents
Measure
ERROR CODE AND TROUBLESHOOTING