4.7.20

Filling developer unit with developer material

(1)
Rotate the gear on the rear side of the
developer unit to the direction of the arrow
while filling the developer unit with the
developer material. Spread out the developer
material over the developer sleeve.
Remarks:
Filling the developer material by replacing
with the cartridge is also available for 23LA/
23LM/28LM/23HA/28HA.
4.7.21
Auto-toner sensor (S4)
(1)
Remove the developer material.
 P. 4-59 "4.7.19 Removing developer
material"
(2)
Place the developer unit upside down.
Release the harness from the harness guide
and then take off the auto-toner sensor [1] by
rotating it.
4.7.22
Doctor blade <20L/23L/25L/20H/23H/25H>
(1)
Remove the developer material.
 P. 4-59 "4.7.19 Removing developer
material"
(2)
Remove 2 springs [1] and then take off the
doctor blade [2].