Toshiba e-STUDIO2006 Service Manual page 555

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

05/08
Mode
Element
Sub element
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Sub-
Item
Subitem
Code
code
Temperature drop
Thick paper
2199
2
switching time
setting during
printing (Side
thermistor)
Temperature drop
Thick paper
2199
3
switching time
setting during
printing (Side
thermistor)
Temperature drop
Thick paper
2200
0
setting during
printing (Center
thermistor)
Temperature drop
Thick paper
2200
1
setting during
printing (Center
thermistor)
Temperature drop
Thick paper
2200
2
setting during
printing (Center
thermistor)
Temperature drop
Thick paper
2200
3
setting during
printing (Center
thermistor)
Temperature drop
Thick paper
2201
0
setting during
printing (Side
thermistor)
Temperature drop
Thick paper
2201
1
setting during
printing (Side
thermistor)
Temperature drop
Thick paper
2201
2
setting during
printing (Side
thermistor)
Temperature drop
Thick paper
2201
3
setting during
printing (Side
thermistor)
Temperature control
Plain paper
2205
0
lower limit (at
ordinary
temperature)
Default
Acceptable
Details
value
value
The third drop
40
0-200
The fourth drop
75
0-200
The first drop
1
0-10
The second drop
2
0-10
The third drop
2
0-10
The fourth drop
3
0-10
The first drop
2
0-10
The second drop
3
0-10
The third drop
4
0-10
The fourth drop
5
0-10
Center thermistor
7
0-12
14-1-35
SRAM
Contents
M
Setting value x 5 seconds later: from 0 to 1000 seconds
M
Setting value x 5 seconds: from 0 to 1000 seconds later
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0degrees C to -50
degrees C
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
M
o
Setting value x -5oC: from 0
C to -50oC
M
0: 130 degrees C 1: 135 degrees C 2: 140 degrees C 3:
145 degrees C 4: 150 degrees C 5: 155 degrees C 6:
160 degrees C 7: 165 degrees C 8: 170 degrees C 9:
175 degrees C 10: 180 degrees C 11: 185 degrees C
12: 120 degrees C
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
20L/
20H/
Proce
23L/
23H/
dure
25L
25H
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
4
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents