[B] Image position adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
[SETTINGS] [USER FUNCTIONS] Select [DRAWER] Select [DRAWER1]
Set the paper size to A3/LD. [OK] Set A3/LD for the paper in upper drawer.
(4)
[CANCEL] [CANCEL] Select the upper drawer by pressing [DRAWER]. Press [START]
to make copies.
(5)
Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(6)
Check if the distance B is within the range of 10±0.5 mm.
(7)
If not, use the following procedure to change values and measure the distance B again.
[SETTINGS] (Key in the code [3030]) [START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
[SETTINGS] Select the upper drawer by pressing [DRAWER]. Press [START] to make
copies.
* The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower (approx. 0.04 mm/step).
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
SETTING / ADJUSTMENT
Copied image of the ruler
Feeding direction
Fig.6-10
6 - 16
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved