<23LA/23LM/28LM/23HA/28HA>
Items to check
I1
Whole developer unit
I2
Developer material
I3
Front shield
I4
Oil seal (4 pcs.)
I5
Side shield
* i1.
Developer material
Make sure to perform "05-2390" and take off the process unit before the developer
material is replaced.
After replacing the developer material, be sure to perform the auto-toner adjustment.
 P. 6-2 "6.2 Adjustment of Auto-Toner Sensor"
* i2.
Oil seal (Developer unit)
Mixer unit (Shafts of mixers-1, -2) 4 pcs.
Note:
Lubricate the oil seal only when the oil seal is replaced.
Remarks:
Values under "Replacement" indicate the replacement cycle for the 23LA/23LM/28LM, 23HA /
28HA.
During replacement, coat the oil seal with grease (Alvanian No.2).
(1)
Push in a new oil seal parallel to the
mounting hole section of the developer
frame or outside of the holder.
* Pay attention to the direction in which the
oil seal is attached. (Refer to Fig. 7-17)
(2)
Apply an even coat of grease to the inside
of the oil seal.
Amount: About two small drops
(3)
Wipe off any grease the exudes from the
inside.
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
PREVENTIVE MAINTENANCE (PM)
Cleaning
Lubrication
B
B
AV
B
7 - 22
Replacement
Operation
x1,000
x1,000
check
drive
sheets
count
59/64
115
R
R
Inside
Fig. 7-19
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Parts list
Remarks
<P-I>
16-1
16-3
*i1
16-4
16-23
16-2
*i2
16-1
Developer frame
(Nozzle mixer)
Outside
Grease
Oil seal

Hide quick links: