[B] Adjustment
Simplex copy
(1)
Turn the power ON while pressing [0] and [5] simultaneously.
Press [3044] [START] button.
(2)
When the margin of the copied image (Fig.6-36Copy) is larger than that of the chart (Fig.6-35
Chart (Original)): Enter a value lower than the current one.
When the margin of the copied image (Fig.6-36Copy) is smaller than that of the chart (Fig.6-35
Chart (Original)): Enter a value larger than the current one.
* Changing the value by 1 point moves the margin by 0.2 mm.
(3)
Press the [OK] button.
Duplex copy
(1)
Turn the power ON while pressing [0] and [5] simultaneously.
Key in [3045] [START] [CLEAR/STOP] button
(2)
When the margin of the copied image (Fig.6-36Copy is larger than that of the chart (Fig.6-35
Chart (Original)): Enter a value lower than the current one.
When the margin of the copied image (Fig.6-36Copy) is smaller than that of the chart (Fig.6-35
Chart (Original)): Enter a value larger than the current one.
* Changing the value by 1 point moves the margin by 0.2 mm.
(3)
Press the [OK] button.
Fig.6-35Chart (Original)
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
SETTING / ADJUSTMENT
E
Fig.6-36Copy
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
6 - 46