Toshiba e-STUDIO2006 Service Manual page 613

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

05/08
Mode
Element
Sub element
08
Setting
System
Network
mode
08
Setting
System
Network
mode
08
Setting
System
Network
mode
08
Setting
System
Network
mode
08
Setting
System
Maintenance General
mode
08
Setting
System
Maintenance Remote-controlled
mode
08
Setting
System
Maintenance RDMS
mode
08
Setting
System
Maintenance Remote-controlled
mode
08
Setting
System
Maintenance Remote-controlled
mode
08
Setting
System
Maintenance Remote-controlled
mode
08
Setting
System
Network
mode
08
Setting
System
Maintenance General
mode
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Sub-
Item
Subitem
Code
code
9525
-
DHCP
9581
SMTP
9584
POP3
9585
9601
-
9604
-
service
9605
-
9606
-
service
9607
-
service
9608
-
service
DHCP
9694
9700
-
Default
Acceptable
Details
value
value
Display of MAC
-
-
address
Enabling server's IP
1
1-2
address acquired by
DHCP
SMTP Server Option
2
1-2
(69) Simple Mail Server
Address
POP3 Server Option
2
1-2
(70) Post Office Server
Address
Equipment number
-
9 digits
(serial number) display
Enabling/disabling a
1
0-1
service notification
Sending error contents
0
0-1
of equipment
Setting total counter
-
-
transmission interval
Email destination
-
-
address 2
Email destination
-
-
address 3
Enabling server's IP
1
1-2
address acquired by
DHCP
Service technician
0
-
telephone number
14-1-93
SRAM
Contents
-
(**: **: **: **: **: **)
The address is displayed as above. 6-byte data is divided
by colon.
-
NetBIOS over TCP/IP Name Server option (44) = Primary
and Secondary Wins NAME
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
-
OFF/ON
1: Valid
2: Invalid
-
OFF/ON
1: Valid
2: Invalid
SYS
Fist digit: Production country (fixed)
Second digit: Model (fixed)
Third digit: Month (variable)
Fourth to ninth digit: serial number (variable)
This can be also entered with 05-9043.
SYS
0: Disabled
1: Enabled
<Default value>
NAD/MJD: 1
Others: 0
SYS
0: Disabled
1: Enabled
SYS
(Hour/Hour/Minute/Minute)
SYS
Maximum 192 letters
SYS
Maximum 192 letters
-
DNS domain name Option (15) DNS domain name of the
client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
SYS
A telephone number can be entered up to 32 digits.
Use the [*] button to change the character mode, and then
use the [#] button to enter a hyphen(-).
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
20L/
20H/
Proce
23L/
23H/
dure
25L
25H
2
-
Y
12
-
Y
12
-
Y
12
-
Y
11
Y
Y
1
-
Y
1
-
Y
1
-
Y
11
-
Y
11
-
Y
12
-
Y
11
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507