05/08
Mode
Element
Sub element
08
Setting
Process
Development Toner near empty
mode
08
Setting
Process
Fuser
Fusing correction
mode
control time
immediately after
warming-up
08
Setting
Process
Fuser
Fusing correction
mode
control time
immediately after
warming-up
08
Setting
Process
Fuser
Correction of
mode
temperature rising
prevention (Latest
value)
08
Setting
Process
Fuser
Correction of
mode
temperature rising
prevention (Latest
value)
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Sub-
Item
Subitem
Code
code
5156
3
Fine adjustment
ofthreshold
fordisplaying
remainingtoner and
toner nearempty
5210
0
Temperature correction
5210
1
Maximum time of lamp
ON
5337
0
Ready
5337
1
Printing
5469
-
Low power
consumption control
5497
0
Low power
consumption control:
Lamp maximum ON
time (Center)
5497
1
Low power
consumption control:
Lamp maximum ON
time (Side)
5497
2
Low power
consumption control:
Lamp maximum ON
time (Center)
Default
Acceptable
Details
SRAM
value
value
100
50-150
M
2
0-10
M
2
0-10
M
0
0-15
M
0
0-15
M
1
0-1
M
10
1-50
M
10
1-50
M
10
1-50
M
14-2-61
Contents
Adjusts the threshold value for displaying remaining
amount of toner and toner near empty. Display threshold
value = default threshold value x setting value/100 (unit: %)
50: Setting value x 0.5
100: Setting value x 1.0
150: Setting value x 1.5
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
0: Disable 1: 1 min. 2: 2 min. 3: 3 min. 4: 4 min. 5: 5 min. 6:
6 min. 7: 7 min. 8: 8 min. 9: 10 min. 10: 15 min.
o
o
o
o
o
o
0: 0
C 1: -1
C 2: -2
C 3: -3
C 4: -4
C 5: -5
C 6: -6
o
o
o
o
o
-7
C 8: -8
C 9: -9
C 10: -10
C 11: -11
C 12: -12
o
o
o
13
C 14: -14
C 15: -15
C
o
o
o
o
o
o
0: 0
C 1: -1
C 2: -2
C 3: -3
C 4: -4
C 5: -5
C 6: -6
o
o
o
o
o
-7
C 8: -8
C 9: -9
C 10: -10
C 11: -11
C 12: -12
o
o
o
13
C 14: -14
C 15: -15
C
This code is used when using low power consumption
control. Note that inconsistent fusing may occur if the fuser
roller temperature is low. Use the above default value,
unless otherwise required.
0: Invalid, 1: Valid
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Proce
23LM/
23HA/
23LA
dure
28LM
28HA
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
o
14
Y
Y
Y
C 7:
o
C 13: -
o
14
Y
Y
Y
C 7:
o
C 13: -
1
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y

Hide quick links: