(5)
Place the fuser unit facing the original
direction, take off the base unit [1].
Notes:
When installing the base unit, make sure that
the sheets [1] are attached as references of
the rib [2] and boss [3].
4.8.6

Separation finger

(1)
Take off the base unit.
 P. 4-82 "4.8.5 Base unit"
(2)
Pull out the separation finger [1] from the
groove.
(3)
Remove the spring [2].
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
[1]
Fig. 4-220
[2] [2]
Fig. 4-221
[1]
Fig. 4-222