e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Sub-
Item
Subitem
Code
code
5497
3
Low power
consumption control:
Lamp maximum ON
time (Side)
5497
4
Low power
consumption control:
Lamp maximum ON
time (Center)
5497
5
Low power
consumption control:
Lamp maximum ON
time (Side)
5497
6
Low power
consumption control:
Lamp maximum ON
time (Center)
5497
7
Low power
consumption control:
Lamp maximum ON
time (Side)
5498
0
Low power
consumption control:
Lamp maximum OFF
time (Center)
5498
1
Low power
consumption control:
Lamp maximum OFF
time (Side)
5498
2
Low power
consumption control:
Lamp maximum OFF
time (Center)
5498
3
Low power
consumption control:
Lamp maximum OFF
time (Side)
Default
Acceptable
Details
SRAM
value
value
10
1-50
M
10
1-50
M
10
1-50
M
10
1-50
M
10
1-50
M
22
1-50
M
22
1-50
M
20
1-50
M
20
1-50
M
14-2-62
Contents
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Proce
23LM/
23HA/
23LA
dure
28LM
28HA
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y
4
Y
Y
Y

Hide quick links: