6.6

Image Quality Adjustment (Scanning Function)

6.6.1
Gamma balance adjustment
The density is adjusted by adjusting the gamma balance. The adjustment is performed by selecting its
density area from the following: low density, medium density and high density.
Black
Original mode
Text/Photo
Text
7485-0
7486-0
7485-1
7486-1
7485-2
7486-2
Notes:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
Procedure is same as that of  P. 6-26 "6.4.5 Gamma balance adjustment".
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Gray
Item to be
Scale
adjusted
Photo
7487-0
7488-0
Low density
7487-1
7488-1
Medium density
7487-2
7488-2
High density
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
6 - 31
<Adjustment Mode (05)>
Remarks
The larger the value is, the density of
the item to be adjusted becomes darker.
Acceptable values:
0 to 255 (Default: 128)