Light Volume Adjustment Of Scanner Led - Toshiba e-STUDIO2006 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2006:
Table of Contents

Advertisement

[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [SETTUNGS]
button, immediately after starting the Adjustment Mode (05), single-sided test copying can be
performed (normal copy mode).
<Operation keys>
0
5
POWER
1
Digital keys
: Enter codes.
START
Digital keys : Enter adjustment
values.
( CLEAR/STOP Use to make corrections)
OK
Value 128 is stored
replacing values 130.
SETTINGS
START
If the test copy does not
satisfy the specified values,
return to step
repeat the adjustment
procedure.
Power OFF/ON : Exit the Adjustment Mode.
6.3.2

Light volume adjustment of scanner LED

Perform the light volume adjustment of scanner LED according to the following procedure.
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in a code "3219" and press the [START] button. The automatic adjustment starts. When the
adjustment is completed, "COMPLETED" appears.
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Test copy
1
and
Fig.6-6
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
6 - 5
<Display>
TEST MODE A
MC=
TEST MODE A
MC=
Code No.
4000
TEST MODE A
MC=4000
Default value
128
TEST MODE A
TEST MODE A
CLEAR/STOP
MC=4000
MC=4000
130
TEST MODE A
MC=
Test
1
1
100 %
A4
AUTO EXPOSURE
TEXT
SETTING / ADJUSTMENT
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents