Operation flow
Load A4 or LT size paper into
Step 0
the cassette, set the cassette
paper size, then turn OFF the
power.
Remove the used EPU from
the equipment. Set the new
EPU in the equipment, then
close the front cover.
Turn ON the power while
pressing [Function clear] and
Step 1
[START] buttons.
When the authentication
screen appears, enter a service
password and press [OK].
The authentication screen is
displayed. Press the [OK].
The developer material is filled
from the developer cartridge.
Start auto-toner sensor
Step 2
adjustment.
Open the front cover, then
set the toner cartridge.
Press [OK].
Step 3
Press [OK].
Step 4
Place the printed gamma chart
on the original glass, then
press [OK].
Step 5
Press the [ON/OFF] button
for a few seconds.
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Display transition of control panel
EPU MODE
EPU MODE
OPEN FRONT COVER
REMOVE
DEV. CARTRIDGE
EPU MODE
SET TONER
CARTRIDGE
CLOSE FRONT COVER
EPU MODE
PRESS [OK]
OK
EPU MODE
SET A4/LT IN DRAWER
PRESS [OK]
OK
EPU MODE
PRINTING
EPU MODE
SET TEST CHART
CLOSE COVER
PRESS [OK]
OK
EPU MODE
WAIT
EPU MODE
TURN OFF THE POWER
Fig. 7-10
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
7 - 9
Behavior flow of equipment
Starts EPU mode
Automatic toner
adjustment
Clears counters of
consumables in the EPU
Prints the gamma chart
Reads the gamma chart,
then performs automatic
gamma adjustment
Power off