Management Acl - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

● Source Port Min.
Shows the lowest possible port number of the source port.
● Source Port Max.
Shows the highest possible port number of the source port.
● Dest. Port Min.
Shows the lowest possible port number of the destination port.
● Dest. Port Max.
Shows the highest possible port number of the destination port.
● Message Type
Shows a message type to decide the format of the message.
● Message Code
Shows a message code to specify the function of the message.
● DSCP
Shows a value for classifying the priority.
Steps in configuration
Follow the steps below to assign an ACL rule to an interface:
1. Select the interface from the "Interface" drop-down list.
2. Select the ACL rule in the "Add Rule" drop-down list.
3. Click the "Add" button. A new entry is generated in the table.
Follow the steps below to remove an ACL rule from an interface:
Note
active rules
You cannot delete active rules.
1. Select the interface from the "Interface" drop-down list.
2. Select the ACL rule in the "Remove Rule" drop-down list.
3. Click the "Remove" button. The corresponding entry is removed in the table.
5.8.7

Management ACL

Description of configuration
On this page, you can increase the security of your device. To specify which station with which
IP address is allowed to access your device, configure the IP address or an entire address
range.
You can select the protocols and the ports of the station with which it is allowed to access the
device. You define the VLAN in which the station may be located. This ensures that only certain
stations within a VLAN have access to the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Configuring with Web Based Management
5.8 The "Security" menu
477

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xm-500

Table of Contents