Siemens SCALANCE XM-400 Configuration Manual page 102

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The following fields are displayed:
● Port
Shows the port to which the following information relates. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Link Check
Shows whether the Link Check function is enabled or disabled.
● OperState
Shows the status of the Link Check function. The following statuses are possible:
– Disabled
– Enabled
– Running
– Faults
● Frames in
Shows how many Link Check test frames were received.
● Frames out
Shows how many Link Check test frames were sent
102
The function is disabled.
The function is enabled. The connection partner has not yet confirmed the monitoring.
The function is enabled. The connection monitoring is enabled. The outgoing and
incoming test frames are counted and matched up.
The function is enabled. Link Check has detected a fault on the monitored section and
turned off the port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12