● Inside Global Port
Shows the port that will be assigned to the Inside Global Address.
● Description
Shows a a description for the port translation.
Procedure
To create a static port translation, proceed as follows:
1. Select the a NAT interface from the "Interface" drop-down list:
2. In "Inside Local Address" enter the actual address of the device that should be reachable
from external.
3. Select a service.
4. Depending on your selection in the "Service" drop-down list specify the start, end and inside
global port.
5. Select a protocol.
6. Enter a description for the port translation.
5.6.4

Static Routes

Static route
On this page, you create the static IPv4 routes.
Description of the displayed values
The page contains the following boxes:
● Destination Network
Enter the network address of the destination that can be reached via this route.
● Subnet Mask
Enter the corresponding subnet mask.