Siemens SCALANCE XM-400 Configuration Manual page 107

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Description of the displayed values
The table has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module number
and the port number, for example port 0.1 is module 0, port 1.
● Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error type.
In the columns of the table, a distinction is made according to the following error types:
– Oversize
– Fragments
– Jabbers
– Collisions
Description of the button
"Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
CRC
Packets whose content does not match the CRC checksum.
Undersize
Packets with a length less than 64 bytes.
Packets discarded because they were too long.
Packets with a length less than 64 bytes and a bad CRC checksum.
VLAN-tagged packets with an incorrect CRC checksum that were discarded because
they were too long.
Collisions that were detected.
Configuring with Web Based Management
5.3 The "Information" menu
107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xm-500

Table of Contents