Siemens SCALANCE XM-400 Configuration Manual page 204

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuring with Web Based Management
5.4 The "System" menu
● SNTP Server Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the SNTP server.
● SNTP Server Port
Enter the port of the SNTP server.
The following ports are possible:
– 123 (standard port)
– 1025 to 36564
● Primary
The check mark is set for the SNTP server that you create first. If several SNTP servers
have been created, the primary server is queried first.
Procedure
1. Click the "SNTP Client" check box to enable the automatic time setting.
2. In the "Time Zone" input box, enter the local time difference to world time (UTC). The input
format is "+/-HH:MM" (for example +02:00 for CEST), because the SNTP server always
sends the UTC time. This time is then recalculated and displayed as the local time based
on the specified time zone. You configure the daylight saving time switchover on the pages
"System > System Time > DST Overview" and "System > System Time > DST
Configuration". You also need to take this into account when completing the "Time Zone"
input box.
3. Select one of the following options from the "SNTP Mode" drop-down list:
– Poll
– Listen
4. In the "Poll Interval[s]" input box, enter the time in seconds after which a new time query is
sent to the time server.
5. In the "SNTP Server Address" input box, enter the IP address or the FQDN of the SNTP
server whose frames will be used to synchronize the time of day.
6. Click the "Create" button.
A new row is inserted in the table for the SNTP server.
7. In the "SNTP Server Port" column, enter the port via which the SNTP server is available.
The port can only be modified if the IPv4 address or the FQDN name of the SNTP server
is entered.
8. Click the "Set Values" button to transfer your changes to the device.
204
For this mode, you need to configure the following:
- time zone difference (step 2)
- query interval (step 4)
-time server (step 5)
- Port (step 7)
- complete the configuration with step 8.
For this mode, you need to configure the following:
- time difference to the time sent by the server (step 2)
- time server (step 5)
- port (step 7)
- complete the configuration with step 8.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12