Siemens SCALANCE XM-400 Configuration Manual page 273

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Table 2 has the following columns:
● Port
Shows all available ports. The port is made up of the module number and the port number,
for example port 0.1 is module 0, port 1.
● Setting
Enable or disable the function for this port.
Steps in configuration
To configure a port as a tunnel port proceed as follows:
1. Change to the page "Layer 2 > VLAN > General".
2. Configure the Bridge mode "Provider".
3. Click the "Set Values" button.
The layer 2 port settings (VLAN, Spanning Tree) are restored to the factory defaults and
the device is restarted.
4. Change to the page "Layer 2 > VLAN > General".
5. Enter the required VLAN ID.
6. Click the "Create" button.
7. Change to the page "Layer 2 > VLAN > Port Based VLAN".
8. For the port select the port VID of the created VLAN.
9. For the port in "Acceptable Frames" select the setting "Untagged and Priority Tagged Only".
10.Click the "Set Values" button.
11.Change to the page "Layer 2 > VLAN > General".
12.For the port in the required VLAN, select the setting "U" (uppercase).
13.For the port in all other VLANs, select the setting "-".
14.Click the "Set Values" button.
15.Disable the following protocols on the port:
– On the page "Layer 2 > VLAN > GVRP" the check box beside "Setting".
– On the page "Layer 2 > Spanning Tree > CIST Port" the check box beside "Spanning
– On the page "Layer 2 > Multicast > GMRP" the check box beside "Setting".
16.Change to the page "System > Ports > Configuration"
17.Select the required port.
18.Select the Port Type "Switch-Port PVLAN Access".
19.Click the "Set Values" button.
20.Change to the page "Layer 2 > Provider-Bridge > Tunnel-Ports".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
Tree Status".
Configuring with Web Based Management
5.5 The "Layer 2" menu
273