Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed boxes
The page contains the following boxes:
● Area ID
Select the ID of the area from the drop-down list. You specify the ID on the "Areas" tab.
● Subnet Address
Enter the IPv4 address of the network that will be grouped.
● Subnet mask
Enter the subnet mask of the network that will be grouped.
This table contains the following columns:
● Select
Select the row you want to delete.
● Area ID
Shows the ID of the area.
● Subnet Address
Shows the IP address of the network that will be grouped.
● Subnet Mask
Shows the subnet mask of the network that will be grouped.
● Advertise
Enable this option to advertise the grouped network.
Steps in configuration
1. Select the ID of the area from the drop-down list.
2. Enter the IP address of the network that will be grouped.
3. Enter the subnet mask of the network that will be grouped.
4. Click the "Create" button. A new entry is generated in the table.
5. Enable the "Advertise" option to advertise the grouped network.
6. Click the "Set Values" button.