Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
1. Select the "Dynamic MAC Aging" check box.
2. Enter the time in seconds in the "Aging Time[s]" input box.
3. Click the "Set Values" button.
5.5.9

Ring redundancy

5.5.9.1

Ring

Rules for ring redundancy
Factory settings
● The factory setting defines MSTP as the redundancy method.
● With SCALANCE XM-400, the factory setting defines ports P1.1 and P1.2 as ring ports.
● With SCALANCE XR-500, the factory setting defines ports P0.1 and P0.2 as ring ports.
Enabling redundancy
You can enable ring redundancy as follows:
● using the WBM
● using the CLI
● using the SELECT/SET button
● using a PROFINET configuration download
Configuration of ring redundancy