Description of the displayed boxes
The following functions are possible:
● Restore Factory Defaults
Enable or disable the "Restore Factory Defaults" function with the Select/set button.
● Redundancy Manager
Enables/disables the redundancy manager function.
● Set Fault Mask
Enable or disable the function "Define fault mask via the LED display" with the SELECT/
SET button.
Steps in configuration
1. To use the required functionality, select the corresponding check box.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 05/2017, C79000-G8976-C248-12
CAUTION
Button function "Restore Factory Defaults" active during startup
If you have disabled this function in your configuration, disabling is only valid during
operation. When restarting, for example after power down, the function is active until the
configuration is loaded so that the device can inadvertently be reset to the factory settings.
This may cause unwanted disruption in network operation since the device needs to be
reconfigured if this occurs. An inserted PLUG is also deleted and returned to the status
as shipped.
CAUTION
Resetting with WBM and CLI
if you have disabled the "Restore Factory Defaults" in your configuration, the disabling
does not apply to the CLI command "Restart" and for the WBM page "System > Restart".
This means that the device can inadvertently be reset to the factory defaults. This may
cause unwanted disruption in network operation since the device then needs to be
reconfigured. An inserted PLUG is also deleted and returned to the status as shipped.
Configuring with Web Based Management
5.4 The "System" menu
211