Device Management; Connecting To The Device - Siemens SIMATIC NET RUGGEDCOM RS900G Equipment Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS900G:
Table of Contents

Advertisement

Device Management

This section describes how to connect to and manage the device.
3.1

Connecting to the Device

The following describes the various methods for accessing the RUGGEDCOM RS900G
console and Web interfaces on the device. For more detailed instructions, refer to the
"RUGGEDCOM RS900G User Guide" for the RUGGEDCOM RS900G.
Serial Console Port
Connect a PC or terminal directly to the serial console port to access the boot-time
control and RUGGEDCOM ROS console interface.
The serial console port is intended to be used only as a temporary connection during
initial configuration or troubleshooting, and should only be used in a safe area (as
defined by IEC 60079-0, Edition 6.0).
The serial console port implements RS-232 DCE (Data Communication Equipment) on
a DB9 connector. Use the following settings to connect to the port:
Speed
Data Bits
Stop Bit
Parity
Flow Control
Terminal ID
RUGGEDCOM RS900G
Equipment Manual, 10/2023, C79000-G8976-1025-10
NOTICE
57600 baud
8
1
None
Off
VT100
3
15