Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes:
● EtherNet/IP Device Diagnostics
Shows whether EtherNet/IP is enabled ("On") or disabled ("Off").
● EtherNet/IP Device Diagnostics for next boot
Set whether EtherNet/IP will be enabled ("On") or disabled ("Off") after the next device
restart.
Note
EtherNet/IP and PROFINET
When EtherNet/IP is turned on, PROFINET is turned off. The switchover from EtherNet/IP
and PROFINET has no effect on DCP.
Note
PROFINET AR Status
If a PROFINET connection is established; in other words the PROFINET AR status is
"Online", you cannot enable EtherNet/IP.
● Restart with EtherNet/IP Defaults
Click this button to restore the default settings of the EtherNet/IP profile and to restart the
device. You must confirm the restart in a dialog box. The dialog box displays these settings
specially made for operation with the EtherNet/IP protocol.
5.4.19

PLUG

5.4.19.1

Configuration

NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is detected
that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the device,
the device changes to a defined error state following the restart.
228
NOTICE
By resetting all the settings to the default settings of a profile, the IP address is also lost.
Following this, the device can only be accessed via the serial interface, using the Primary
Setup Tool or using DHCP.
With the appropriate attachment, a previously correctly configured device can cause
circulating frames after the reset and therefore the failure of the data traffic.